Plan a two-occupant chamber installation with the TimePod Ultra 2. Its listed hard-shell configuration combines dual air handlers, dual oxygen concentrators and in-session communication features. Whole-unit or manufacturer-arranged split delivery offers site-access options, subject to a professional installation assessment. Intended use, medical suitability and operating requirements must be confirmed before purchase.
Why Customers Choose This Product
- Listed two-person chamber configuration.
- Stainless steel and PC engineering plastic construction.
- Dual air handlers and dual oxygen concentrators.
- Call button and speaker communication.
- Listed cooling and dehumidification functions.
- Whole-unit or split delivery options, subject to arrangement.
Product Highlights
Two-occupant layout
The source identifies a two-user chamber and references electrically adjustable seating. Confirm usable interior dimensions, seat and occupant limits, and the supplied seating configuration in writing.
Listed 2.0 ATA capability
The maximum listed pressure is 2.0 ATA. This is an equipment specification, not a recommended treatment pressure, session duration or health benefit.
Dual air and oxygen systems
The listing describes two air handlers and two oxygen concentrators with filtration, cooling and dehumidification. Confirm how the host units, component ratings and approved oxygen-delivery system apply to the delivered configuration.
Monitoring and communication
A pressure gauge, manual regulation valve, emergency relief valve, call button and speaker are listed. These features do not replace qualified supervision, training or documented emergency procedures.
Site-access planning
The source offers delivery as one completed unit or divided in half for on-site assembly. Split assembly must be manufacturer-authorized and completed by qualified personnel with required inspection and commissioning.
Specifications
- Product: TimePod Ultra 2
- Vendor: MedEq Fitness
- Base model: XH18220-2
- Platform identified in source: OxyPrime/OxyRevo; confirm exact manufacturer
- Type: hard-shell hyperbaric chamber
- Listed occupancy: two users; individual fit and load limits require confirmation
- Maximum listed pressure: 2.0 ATA
- Chamber dimensions in source: 2200 by 1600 by 1700 mm; axes and interior/exterior reference require confirmation
- Alternate source dimensions: 83 by 67 by 69 in; do not match the metric set and require reconciliation
- Listed chamber weight: 820 kg; included component scope requires confirmation
- Materials: stainless steel and PC engineering plastics
- Air system: two air handlers
- Oxygen system: two concentrators
- Host-unit dimensions listed: 766 by 350 by 750 mm; confirm per-unit application
- Host-unit weight listed: 110 kg; confirm per-unit application and whether included in chamber/system weight
- Listed host airflow: 72 L/min; per-unit/system basis and operating conditions not supplied
- Listed oxygen-flow references: 5 and 10 L/min; configuration, per-occupant allocation and output under pressure require confirmation
- Filtration: air and activated-carbon filter elements, as listed
- Host functions listed: oxygen supply, air supply, purification, anion, dehumidification and refrigeration; performance documentation requires confirmation
- Controls: manual pressure regulation and emergency relief valve
- Monitoring: pressure gauge/barometer
- Communication: call button and speaker
- Seating: electrically adjustable positions referenced in source; confirm included seating
- Delivery configurations: completed unit or manufacturer-arranged split assembly
- Color selections: White, Black, Silver, Gray and Navy
- Listed limited warranty: two years for manufacturing defects on chamber, control panels, compressor, concentrator and dehumidifier; subject to written configuration-specific terms, exclusions and destination
Ideal For
Buyers planning a professionally assessed two-occupant chamber installation where the intended use is permitted and supported by qualified medical evaluation, appropriate facilities, trained operators and supervision. Two-person capacity alone does not establish pediatric suitability, clinical approval or suitability for unsupervised residential use.
Important Information
Hyperbaric pressure and supplemental oxygen carry serious risks, including pressure injury and fire. Obtain assessment from a clinician qualified in hyperbaric medicine for every occupant and follow documented intended use, contraindications and operating limits. Do not select pressure, oxygen flow or session duration from this description. Medical clearance is needed for an accompanying occupant as well as the primary user.
Obtain model-specific regulatory and pressure-vessel documentation before purchase. Confirm any prescription, operator, facility, inspection and installation requirements with qualified professionals. No FDA clearance, medical-grade status or approval to treat a condition is established here. Arrange qualified installation, training, commissioning, monitoring, ventilation, communication and emergency planning. Do not operate alone or treat the second occupant as a replacement for a trained external operator.
The source's approximately 100 kPa pressure reference does not specify absolute or gauge pressure and is not an operating instruction. Never open the door while pressurized. Follow the manufacturer procedure for returning the chamber to ambient pressure and verifying the gauge reference before opening; a zero gauge reading is not zero absolute pressure. Do not improvise rapid decompression or modify valves or fittings.
Keep smoking, flames, sparks and ignition sources away. Use only manufacturer-approved oxygen delivery, electrical equipment, clothing, accessories and cleaning products for this exact chamber. Do not introduce unapproved electronics, oils or combustible materials. Confirm oxygen monitoring, fire precautions and emissions documentation for any anion module. Do not pressurize the chamber with oxygen unless explicitly authorized by the manufacturer and applicable requirements.
Reconcile the conflicting dimension sets before arranging freight. Have qualified professionals assess delivery paths, lifting equipment, room and host-unit clearances, structural floor support, total installed weight, electrical supply and service access. Electrical ratings and maximum occupant/seat loads are not supplied. Do not assume the host weight or flow ratings apply twice or are included in the chamber weight.
The source mentions optional mask-based BIBS delivery and additional environmental options; these are not established as included. Confirm exact components, compatible options, written warranty, installation services and current delivery terms. Follow the model-specific inspection, cleaning, filter replacement and service schedule; remove damaged or malfunctioning equipment from service.
Frequently Asked Questions
How many occupants are listed?
The source specifies two users. Confirm seating fit, individual and total load limits, intended use and medical suitability for every occupant; pediatric suitability is not established.
What pressure capability is listed?
The maximum listed pressure is 2.0 ATA. This is not a treatment recommendation; operating pressure and procedures require qualified guidance and model-specific documentation.
Are the chamber dimensions consistent?
No. The source lists 2200 by 1600 by 1700 mm and 83 by 67 by 69 in, which do not match. Obtain a confirmed dimensional drawing before planning access or installation.
Can it be delivered in sections?
The source describes whole-unit delivery or division in half for on-site assembly. Confirm the supplied format and arrange manufacturer-authorized professional assembly, inspection and commissioning.
Is mask-based BIBS oxygen delivery included?
The source describes BIBS as an optional upgrade, not an established included component. Confirm its availability, exact contents and compatibility for the ordered configuration.
If this two-occupant format fits your professionally assessed requirements, confirm the configuration, documentation and installation plan before selecting your color and ordering.
No treatment or health outcomes are promised. Hyperbaric pressure and oxygen require qualified medical assessment, appropriate training and manufacturer-directed operation. This description is not medical advice.